Back to search

University of Toronto

Towards Unspecific Detection of Pathogenic Agents in Environmental Waters

Abstract

dc:description.abstract

The need for effective and efficient techniques for detection of microorganisms in water samples is as strong as ever because the health risk posed by consumption of pathogen contaminated water remains to be a serious threat to the population. The techniques which are currently and commonly used for water-quality monitoring rely on lengthy and time-consuming culturing procedures which do not allow for rapid decision making process. PCR-based methods, DNA sequencing-based methods and Immunofluorescence tests are recently being introduced by different researchers as promising pathogen detection techniques however, these techniques are complex, expensive and can also be time-consuming. One of the research streams focused on for the purpose of pathogen detection in water is biosensor technology. One of the integral properties of biosensors is their high specificity towards their analyte of interest. Although for many applications such a high specificity is a necessity, for some applications such as pathogen detection in water, it can be restrictive and will be considered a limitation. As such a highly specific biosensor will only detect one pathogenic agent and miss the other possible pathogens. In this project, the possibility of using Toll-Like Receptors (TLRs); immunoproteins from higher organisms, as bio-recognition elements in biosensors for detection of a broad class of pathogens in water was evaluated. Toll-Like Receptors recognize and bind to the molecular patterns of pathogens and upon this binding the immune response against that pathogen is initiated. Using TLR3-modified Au sensors, detection and quantification of polyinosinic-polycytidylic acid (Ploy (I:C)); a mimic of dsRNA; the molecular signature of viruses was achieved with a detection limit of 0.18 Âľg mL-1. Also the detection and quantification of lipopolysaccharide (LPS); the molecular signature of Gram-negative bacteria, was possible using TLR4-modified Au sensors. However, TLR4-modified Au sensors were not able to discriminate the LPS samples from E. coli and Salmonella as a result of the unspecific approach to detection (detection of Gram-negative bacteria as a broad class of pathogens and not any specific bacterium). The limit of detection for the quantification was 1.3Ă 10-4 EU mL-1 and 1.5Ă 10-4 EU mL-1 for LPS from E. coli and LPS from Salmonella, respectively. The opportunities, challenges and drawbacks of using TLRs as bio-recognition elements for biosensors for pathogen detection in water also were discussed and a new research work based on multiplexing TLR sensors and pattern recognition was suggested for future work.

Degree

thesis:*
Department dc:contributor.department
Physical and Environmental Sciences
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Amini, Kaveh
Advisor dc:contributor.advisor
  • Kraatz, Heinz-Bernhard

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/76185

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Amini, Kaveh. Towards Unspecific Detection of Pathogenic Agents in Environmental Waters. 2016. https://hdl.handle.net/1807/76185