University of Toronto
Towards Unspecific Detection of Pathogenic Agents in Environmental Waters
Abstract
dc:description.abstractThe need for effective and efficient techniques for detection of microorganisms in water samples is as strong as ever because the health risk posed by consumption of pathogen contaminated water remains to be a serious threat to the population. The techniques which are currently and commonly used for water-quality monitoring rely on lengthy and time-consuming culturing procedures which do not allow for rapid decision making process. PCR-based methods, DNA sequencing-based methods and Immunofluorescence tests are recently being introduced by different researchers as promising pathogen detection techniques however, these techniques are complex, expensive and can also be time-consuming. One of the research streams focused on for the purpose of pathogen detection in water is biosensor technology. One of the integral properties of biosensors is their high specificity towards their analyte of interest. Although for many applications such a high specificity is a necessity, for some applications such as pathogen detection in water, it can be restrictive and will be considered a limitation. As such a highly specific biosensor will only detect one pathogenic agent and miss the other possible pathogens. In this project, the possibility of using Toll-Like Receptors (TLRs); immunoproteins from higher organisms, as bio-recognition elements in biosensors for detection of a broad class of pathogens in water was evaluated. Toll-Like Receptors recognize and bind to the molecular patterns of pathogens and upon this binding the immune response against that pathogen is initiated. Using TLR3-modified Au sensors, detection and quantification of polyinosinic-polycytidylic acid (Ploy (I:C)); a mimic of dsRNA; the molecular signature of viruses was achieved with a detection limit of 0.18 Âľg mL-1. Also the detection and quantification of lipopolysaccharide (LPS); the molecular signature of Gram-negative bacteria, was possible using TLR4-modified Au sensors. However, TLR4-modified Au sensors were not able to discriminate the LPS samples from E. coli and Salmonella as a result of the unspecific approach to detection (detection of Gram-negative bacteria as a broad class of pathogens and not any specific bacterium). The limit of detection for the quantification was 1.3Ă 10-4 EU mL-1 and 1.5Ă 10-4 EU mL-1 for LPS from E. coli and LPS from Salmonella, respectively. The opportunities, challenges and drawbacks of using TLRs as bio-recognition elements for biosensors for pathogen detection in water also were discussed and a new research work based on multiplexing TLR sensors and pattern recognition was suggested for future work.
Degree
thesis:*- Department dc:contributor.department
- Physical and Environmental Sciences
- Year dc:date.issued
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Amini, Kaveh
- Advisor dc:contributor.advisor
-
- Kraatz, Heinz-Bernhard
Subjects
dc:subject × 5Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/76185