Back to search

University of Toronto

A Non-invasive Validation Method for Conductivity Imaging

Abstract

dc:description.abstract

Conductivity imaging is of great potential importance in many biomedical applications, such as in the early diagnosis of breast tumors and the diagnosis and therapy planning for cardiac arrhythmia. With significant progress in conductivity imaging, there is a growing need for a quantitative non-invasive validation method. A new non-invasive validation procedure has been developed to assess the accuracy of any low-frequency conductivity imaging method. This procedure is based on Current Density Imaging, a well-established procedure to measure currents inside an object. A testing current is applied to the object under study. The proposed validation protocol compares measurements of this testing current against that computed using a forward solver. The forward solver computes the current using the conductivity determined by the method under test and the boundary conditions for the measured current. We implemented the proposed procedure on three conductivity imaging methods. The first, Current Density Impedance Imaging (CDII), uses measurements of two currents to determine the isotropic conductivity of the structure under test. The second, Diffusion Tensor Current Density Impedance Imaging (DT-CD-II), was recently developed in our laboratory for imaging anisotropic conductivities and relies on the measurement of the diffusion tensor and of two currents. The third method requires only the magnitude of one current and of the corresponding voltage on the boundary of the object to determine an isotropic conductivity, and will be referred to as MCDII. The validation method was first tested on earlier experimental data for CDII. It was then used to assess the accuracy of DT-CD-II on experimental data for an anisotropic conductivity. We show that the results of the DT-CD-II reconstruction are better than those obtained using CDII on the same current measurements and assuming the conductivity to be isotropic. The validation procedure was also shown to be applicable to a third, and very different conductivity imaging method (MCDII), that requires only the magnitude of one current and the corresponding boundary voltage. The thesis includes the first three-dimensional numerical implementation of this method. The validation yields a quantitative comparison of its accuracy with that of CDII on the same simulated data.

Degree

thesis:*
Department dc:contributor.department
Biomedical Engineering
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Elsaid, Nahla M. H.
Advisors dc:contributor.advisor
  • Joy, Michael LG
  • Nachman, Adrian I

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/77811

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Elsaid, Nahla M. H.. A Non-invasive Validation Method for Conductivity Imaging. 2016. https://hdl.handle.net/1807/77811