Flow mediated dilatation (FMD) assessment via an MRI integrated signal intensity (IntSI) approach: A comparison with ultrasound

Abstract

dc:description.abstract

Endothelial dysfunction is a precursor of atherosclerosis. Flow mediated dilatation (FMD) is a measure of endothelial function. Ultrasound (US) is often used during FMD studies, but US- FMD is technically challenging. MRI methods for FMD rely on high spatial resolution but this entails a trade off involving temporal resolution and SNR. An adequate temporal sampling frequency is however required to detect the peak dilatation. In this thesis, concepts in hemodynamics and MRI physics were explored in order to develop a reliable MRI-FMD technique that is comparable with US-FMD. The approach was to measure the luminal area as a function of the integrated signal intensity (IntSI) of the lumen, since signal intensity increases with area. An equation was derived to account for concurrent velocity based increases in signal intensity. Phantom studies showed the IntSI technique as a reliable means of measuring the luminal area, provided that certain assumptions are not violated. Next, the IntSI technique was adapted for in vivo application. The popliteal artery was the artery of choice based on its anatomical advantages. The velocity profile and time averaged velocities of the popliteal artery were determined from spectral Doppler analysis, in order to design an in vivo technique that is compatible with the assumptions on which the IntSI technique is based. When applied in vivo, the IntSI technique overestimated luminal area measurements compared to a conventional MRI approach. Numerical optimization was used to obtain a correction factor to account for the bias. Subsequently, the IntSI technique was applied for measuring the luminal area during MRI-FMD and compared with US-FMD. The IntSI technique provided repeatable FMD measurements. Although the thesis did not demonstrate that the popliteal MRI-FMD using the IntSI technique was superior to US-FMD, it was non-inferior to US-FMD.

Degree

thesis:*
Department dc:contributor.department
Medical Science
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Olowoyeye, Omodele Abosede
Advisor dc:contributor.advisor
  • Moody, Alan

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/80764

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Olowoyeye, Omodele Abosede. Flow mediated dilatation (FMD) assessment via an MRI integrated signal intensity (IntSI) approach: A comparison with ultrasound. 2017. https://hdl.handle.net/1807/80764