Back to search

University of Toronto

Fundamental Studies of the Physics of an Argon Microcavity Discharge

Abstract

dc:description.abstract

Simulations of DC microcavity discharges in Ne predict that they are sustained by high energy (beam) electrons, which dominate at low pressure(< 500 Torr). Additional analytical studies of beam-dominated, cold-cathode discharges have identified three primary populations of the electron energy distribution: low-, mid- and high-energy electrons, with only the latter two contributing to the external current. Simulations are conducted in this thesis using COMSOL alongside data from the LXCat plasma database to compute important parameters. It is found that fields are ~10 Vμm-1, while the mean free path lengths of various processes are ~ 10 - 1000's of μm, therefore comparable to microdischarge dimensions. This implies a large rate of loss of energetic electrons as well as a pressure-dependent preference for particular reactions (depending on the gas, ionization rather than excitation). These insights are used to investigate DC microdischarges, which are fabricated as 3×3 arrays of 20×20 μm2 microcavities in silicon using standard semiconductor processing. An effective and reproducible protocol for the residue-free etching polyimide PI 2611 using standard reactive ion etching and an O2/N2 chemistry has been developed. Experiments have been conducted in Ar/air, under varied pressure conditions. Emission from N2(C3Πu) - N2(B3Πg) (N2(C-B)) nitrogen second positive system (SPS) is used as the probe, showing a progressive diminution of the N2( C-B) signal attributed to the decrease in the Ar excitation rate due to the increased population of beam electrons. Voltage-current measurements also reveal characteristics consistent with behaviour expected from the population model of segregated mid- and high-energy electrons. A diatomic ro-vibrational model has been developed based on the Dunham expansion to simulate the N 2(C–B) (0-0) transition. Fits to the spectral data have been used to extract rotational temperature, Trot, whose behaviour under different pressure conditions has been examined. Trot ranges from room temperature to ~1100 K. Trot is found to be least (~ 300 K and flat) at the highest pressure investigated (272 Torr). Other pressures show a gradual increase with applied voltage. A puzzling instability is found at ≥ 300 Torr, unexpected from the literature. Several possible reasons are proposed, but no definitive explanation is currently known.

Degree

thesis:*
Department dc:contributor.department
Materials Science and Engineering
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Muchemu, Michael Nakasala
Advisor dc:contributor.advisor
  • Ruda, Harry

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/89641

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Muchemu, Michael Nakasala. Fundamental Studies of the Physics of an Argon Microcavity Discharge. 2017. https://hdl.handle.net/1807/89641