Back to search

University of Toronto

Spatially Modulated Dose Optimization and Performance Limitations with Robust Targeting Performance for Preclinical Irradiation

Abstract

dc:description.abstract

The flexibility and sophistication of modern external beam radiotherapy treatment planning and delivery methods have advanced techniques to improve the therapeutic ratio. Contemporary dose optimization and calculation algorithms facilitate radiotherapy plans which closely conform the three-dimensional dose distribution to the target, with beam shaping devices and image guided field targeting ensuring the rigor and accuracy of treatment delivery. In general, such advances outpaced the technical ability of preclinical systems to faithfully reproduce the clinical capabilities at the scale required for robust small animal or radiobiological investigations. Evidence for sophisticated, and potentially efficacious, new clinical treatment strategies could not always be gathered from preclinical data owing to the improbability of rigorously scaling the proposed technique to the fidelity required for small animal studies. Within the past decade, several groups have developed dedicated small animal irradiator platforms to redress this imbalance. Such systems are commonly based on on-board computed tomography (CT) approaches to facilitate visualization and radiation targeting with interchangeable collimators incorporating field sizes on the millimeter scale. The integration of these capabilities has laid the foundation for precisely modulating and accurately targeting radiation dose for intricate preclinical studies, but algorithms and methods to do so remain in their infancy. In this thesis, we advance techniques to robustly optimize and accurately deliver spatially varying dose distributions for small animal or radiobiological research. An optimization framework based on empirically measured dose kernel measurements is first developed. The native targeting uncertainty of the microirradiator is then rigorously quantified and an online method to ensure high performance targeting accuracy for all radiation field sizes is demonstrated. Finally, it is proven that the underlying spatial frequency content of a dose kernel fundamentally limits the achievable degree of spatial modulation. This result is refined to define a lower bound in the minimization of a dose optimization objective function and provide a direct, analytic method to estimate the result of such an optimization. The combined results demonstrate that the optimization of complex dose distributions can be quickly estimated, iteratively refined, and automatically delivered with millimetre scale modulation at an accuracy of a tenth of a millimetre.

Degree

thesis:*
Department dc:contributor.department
Biomedical Engineering
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stewart, James Michael Patrick
Advisors dc:contributor.advisor
  • Jaffray, David A
  • Lindsay, Patricia E

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/92096

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Stewart, James Michael Patrick. Spatially Modulated Dose Optimization and Performance Limitations with Robust Targeting Performance for Preclinical Irradiation. 2018. https://hdl.handle.net/1807/92096