University of Toronto
Methods to Evaluate and Increase the RF Safety of Cardiovascular Interventional Devices During MRI
Abstract
dc:description.abstractPercutaneous revascularization could benet greatly from MRI guidance and device tracking, but MRI guidance is currently contraindicated due to RF safety concerns. The success rate of such procedures could be improved by devices designed to exploit the unique features of MRI. Unfortunately such devices require long linear conductive structures, which present a significant risk to the patient in the form of RF heating. A priori safety prediction is impractical in vivo and thus, safety is typically investigated in vitro and extrapolated. A method of remotely predicting safety in situ during an exam would be very beneficial for ensuring safety in patients. A method of increasing the safety of revascularization devices would also be necessary to allow their employment in many clinical scenarios. Techniques are developed and presented in this thesis to enable safe, remote quantification of induced RF current and heating in vivo. Also presented is a technique of increasing the safety of revascularization guidewires without altering mechanical properties. The first technique is a method of analyzing phase artifacts introduced into MRI images by RF current flowing on linear conductive structures. The technique ts a theoretical representation of the phase artifact to an acquired image to quantify the current that induced the artifact. The measured current is then used to predict power deposition and heating. The technique is developed theoretically, and demonstrated with an in vitro feasibility study. Extensions to this phase-based technique are also presented. Sources of unwanted phase artifacts in vivo are discussed and it is demonstrated that a custom imaging sequence is capable of eliminating said artifacts. A feasibility study is presented wherein heating is accurately predicted in several pig experiments, using the custom sequence for current characterization. A novel application of floating RF traps, towards suppressing induced current on guidewires, is also presented. Theory of trap function is developed and veried through modelling and in-vitro experimentation. It is demonstrated that traps can feasibly increase the RF safety of guidewires, without altering the guidewire mechanical properties. Finally, future studies and extensions of the presented techniques towards robust clinical implementation are proposed and discussed.
Degree
thesis:*- Department dc:contributor.department
- Medical Biophysics
- Year dc:date.issued
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Griffin, Greg
- Advisor dc:contributor.advisor
-
- Wright, Graham A
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/92679