University of Toronto
Characterization and clinical applications of textile-based sensors in rehabilitation
Abstract
dc:description.abstractThe focus of much previous research and development in electronic textiles has been on remote sensing and monitoring, while opportunities for textile-mediated feedback to the wearer remained unexplored. Additionally, feasibility with clinical populations had not been reliably demonstrated. This thesis explores validation and clinical testing of fabric- and thread-based mechanical and electrical sensors. While conductive thread-based stretch sensors have been previously described in terms of their overall correlation with existing measurement modalities, the ability of such sensors to predict linear elongation had yet to be investigated. In a characterisation study, we developed an algorithm to predict linear elongation, given sensor resistance. Sensors based on the 5-thread coverstitch predicted linear elongation to within 5% of sensor range. Given the possibility of applying stitched sensors non-destructively to existing garments, further study of these sensors remains worthwhile. In a study combining sensor characterisation and clinical testing, we designed and tested a wearable speech generating device (SGD) incorporating resistive textile-based switches for a nonverbal pediatric participant with vision impairment. In mechanical tests, the best performing textile switch consisted of two layers of woven conductive fabrics and one layer of insulating felt. In testing the SGD with a pediatric participant, communicative interactions were found to be higher with the fabric-based SGD, particularly at school. Tactile differentiability of keys, device wearability, and aesthetic and functional personalization may be promising advantages of fabric-based SGDs for pediatric users. While electrooculography (EOG) is a promising technology for access for individuals with communication disabilities, traditional sensors can be uncomfortable and obtrusive. We therefore explored the use of fabric-based electrodes for measuring EOG in two participants with neuromuscular disabilities. We developed a peak detection algorithm which differentiated blinks based on relevant peak characteristics (peak height, prominence, and width) with minimal training. Results were promising in both participants, with 83–87% precision and 85–86% recall for online sessions. While thread- and fabric-based sensors have demonstrated efficacy for unobtrusive monitoring in healthcare and rehabilitation applications, additional uses in interaction and communication are promising and warrant further exploration.
Degree
thesis:*- Department dc:contributor.department
- Biomedical Engineering
- Year dc:date.issued
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Fleury, Amanda
- Advisor dc:contributor.advisor
-
- Chau, Tom
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/95646