Back to search

University of Toronto

Magnetic Resonance Characterization of Infarct Heterogeneity Using High-Resolution Volumetric Multicontrast Imaging

Abstract

dc:description.abstract

Infarct characteristics identified by gadolinum-enhanced magnetic resonance imaging (MRI) have been increasingly used to inform the management of ventricular tachycardia (VT) in patients with prior myocardial infarction (MI). Gadolinum-enhanced MRI can identify the presence, location, morphology, heterogeneity and size of MI. Heterogenous tissue in the peri-infarct zone has been associated with arrhythmic substrates determined in the electrophysiology study. Recently, the extent of infarct heterogeneity assessed by gadolinum-enhanced MRI has been shown to predict VT inducibility, the occurrence of arrhythmic events and appropriate implantable cardioverter defibrillator (ICD) therapy. However, accurate assessment of infarct heterogeneity is primarily limited by achievable spatial resolution in clinical settings restricted by the time constraints occurring with cardiac and respiratory motion as well as contrast kinetics. This thesis presents new acceleration methods for high-resolution volumetric multicontrast imaging to improve characterization of infarct heterogeneity by gadolinum-enhanced MRI. A new reconstruction using compressed sensing with low rank and spatially varying edge-preserving constraints (CS-LASER) was developed to enable reconstruction of small-scale features from highly accelerated volumetric multicontrast acquisitions. In a pig study, CS-LASER was demonstrated to provide peri-infarct characteristics on multicontrast images with excellent correspondence with histopathology. Furthermore, improved peri-infarct characterization was achieved by advancing reconstruction efficacy and robustness for cases of varying contrast-to-noise ratio (CNR) using compressed sensing and parallel imaging with low rank and spatially varying edge-preserving constraints (CP-LASER). Finally, in a clinical study of 11 patients with chronic MI, it was successfully demonstrated that CP-LASER accelerated volumetric multicontrast imaging achieves an isotropic resolution of 2.2 mm on 1.5T in a single breath-hold, and provides better delineation of infarct characteristics and improved assessment of infarct heterogeneity compared to the conventional two-dimensional (2D) late gadolinium enhancement (LGE) method. The methods presented in this thesis help translate high-resolution volumetric multicontrast imaging toward clinical utility in infarct heterogeneity assessment.

Degree

thesis:*
Department dc:contributor.department
Medical Biophysics
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Li
Advisor dc:contributor.advisor
  • Wright, Graham A.

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/95946

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Zhang, Li. Magnetic Resonance Characterization of Infarct Heterogeneity Using High-Resolution Volumetric Multicontrast Imaging. 2019. https://hdl.handle.net/1807/95946