Back to search

University of Toronto

An Investigation of Bifocal Display Design Parameters for Improving Performance in Minimally Invasive Surgery

Abstract

dc:description.abstract

In minimally invasive surgical procedures, limited access to the surgical site, in combination with high magnification and a narrow field of view, create a challenging operating environment for the surgeons. In particular, it has been observed that surgical instruments are not in the surgeons’ field of view at all times, forcing them to manoeuvre the instruments without direct view of the instruments’ tip position and trajectory, which poses a risk of inadvertently causing injury to internal tissues or organs. This thesis investigates the effectiveness of Bifocal displays for addressing this problem, by displaying a wide field of view to facilitate instrument manoeuvring while concurrently providing the high magnification necessary for performing detailed surgical manipulation tasks. Furthermore, the two design parameters that define the nature of the Bifocal transformation function were explicitly defined and their impact on task performance was systematically investigated. These parameters are the maximum magnification level and the detail-to-total ratio – the latter being the proportion of the screen allocated to the magnified view. An experimental platform was developed to evaluate operator performance in both instrument insertion and detailed manipulation type tasks while using the Bifocal display in an environment analogous to minimally invasive surgery. The results show that the Bifocal display significantly improves performance for instrument insertion. Furthermore, it was found that varying the display detail-to-total ratio significantly impacts performance in both instrument insertion and detailed manipulation tasks, regardless of the magnification level, with performance improving in each task in an asymptotic manner. More importantly, it was confirmed that there exists a performance trade-off between these two types of task as a function of varying the detail-to-total ratio. These findings have important design implications for not only minimally invasive surgery but also analogous applications such as microsurgery or remotely operated space or underwater vehicles.

Degree

thesis:*
Department dc:contributor.department
Mechanical and Industrial Engineering
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bina, Bardia
Advisor dc:contributor.advisor
  • Milgram, Paul

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language.iso
en_ca

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/97109

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bina, Bardia. An Investigation of Bifocal Display Design Parameters for Improving Performance in Minimally Invasive Surgery. 2013. https://hdl.handle.net/1807/97109