Abstract

dc:description.abstract

In the chemical recovery process of kraft pulp mills, electrostatic precipitators (ESPs) are used to remove ash particles from the recovery boiler flue gas. High ash collection efficiency is necessary to minimize particulate emissions. A slight decrease in ESP performance could cause kraft mills to exceed their environmental emissions limits, which in severe cases, can force mills to curtail production until the issue is resolved. Therefore, understanding factors affecting ESP performance is of vital importance to the productivity and sustainability of kraft mills. This thesis work consists of two parts: 1) sensitivity analysis of factors affecting the particle collection efficiency of ESP using the conventional Deutsch-Anderson equation and 2) experimental investigation the effects of various parameters on ESP performance, including flue gas temperature, moisture content and ash chemical composition. Three types of ash were considered: ash with low carbonate and low chloride contents (typical ash), ash with low chloride but high carbonate contents, ash with low carbonate but high chloride contents. Results of sensitivity studies show that increasing the gas temperature decreases the ESP collection efficiency. Of the three types of ash examined, the high carbonate ash is the easiest to capture, followed by high chloride ash and then typical ash. Results of experiments using a bench scale ESP show that 1) increasing the gas temperature increases efficiency, 2) typical ash is the easiest to capture, followed by high carbonate ash and then high chloride ash, and 3) increasing moisture content in the gas improves the collection efficiency. The results also show that ash dielectric constant is as important as ash electrical resistivity in predicting how ash may affect the ESP collection efficiency, and that the sensitivity analysis predictions are improved when more accurate values of dielectric constant are used. From the results of the experiments, equations were derived for estimating the particle migration velocity for a given ESP design. The experimental results imply that the ESP collection efficiency decreases with an increase in black liquor firing load, increases as a result of the deposits that form on the heat exchanger tubes, and is not affected by sootblowing.

Degree

thesis:*
Department dc:contributor.department
Chemical Engineering Applied Chemistry
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jaroudi, Ezzat
Advisors dc:contributor.advisor
  • Evans, Greg
  • Tran, Honghi

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/97531

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jaroudi, Ezzat. Effect of Fly Ash Composition and Flue Gas Conditions on Removal Efficiency of Electrostatic Precipitators in Kraft Recovery Boilers. 2019. https://hdl.handle.net/1807/97531