Back to search

University of Toronto

Evaluation and Application of Alternative Drinking Water Biofilter Monitoring Techniques

Abstract

dc:description.abstract

Drinking water biofiltration research has increased dramatically in the past decade as new monitoring techniques have become available, resulting in widespread implementation at municipal treatment facilities. However, biofiltration is still considered a “black-box” technology which offers limited process control. This research examined biofiltration using a variety of techniques to develop a practical understanding of the underlying biological processes and provide guidance for improved design and operation. This research focussed on three primary topics: i) modelling processes critical to biofiltration, ii) applying biological monitoring to improve treatment, and iii) demonstrating benefits beyond providing improved water quality. Initial studies evaluated the application of a biofilter scaling model to determine the significance of biofilm shear loss and mass transport resistance with respect to a variety of biomass (density, function, and community composition) and water quality (organics, nutrients, disinfection by-product formation potential) parameters. Biofilm shear loss was observed to be the critical design parameter when scaling biofilter processes from pilot- to bench-scale, as enzyme activity, indicative of biological function, was not equivalent to pilot filters when mass transport resistance was deemed to have primacy. Subsequent studies further examined enzyme activity as a monitoring parameter for biofilter function; esterase and phosphatase were identified as being quantifiable and meaningful. Combining enzyme activity and filter empty bed contact time (EBCT) was defined as “Effective Activity”. Effective esterase activity was observed to correlate to carbon removal whereas effective phosphatase activity was correlated with phosphate removal. These relationships were observed for a range of pre-treatments (coagulation, pre-ozonation, ultrafiltration, UV), filter media (granular activated carbon, anthracite or sand) and operating conditions (EBCT, daily shutdown) suggesting that effective activity may serve as a useful design and operation parameter. Finally, two water treatment facilities were examined to determine potential energy cost savings associated with cyclical biofilter operation. It was shown that production costs could be reduced by >20% by scheduling production during low energy cost periods (e.g. 10 PM – 7 AM). This research demonstrated that monitoring biofilter enzyme activity may allow for optimal design and operation when compared to other monitoring parameters. Cyclically operated biofilters may dramatically reduce operating costs without impacting water quality.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • McKie, Michael James
Advisors dc:contributor.advisor
  • Andrews, Robert C
  • Andrews, Susan A

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/97560

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

McKie, Michael James. Evaluation and Application of Alternative Drinking Water Biofilter Monitoring Techniques. 2019. https://hdl.handle.net/1807/97560