Back to search

Texas Tech University

X-ray microtomographic image analysis for identification of cotton contaminants

Abstract

dc:description.abstract

Technologies currently used for cotton contaminant assessment suffer from some fundamental limitations. These limitations severely restrict the ability of existing technologies to accurately detect and classify contaminants in cotton. Such inaccuracies result in the misassessment of the cotton quality, and have a serious impact on its economic value. The fundamental limitations of existing methods include the inability to detect contaminants under the surface of cotton, the inability to accurately measure shapes and sizes, sample preparation requirements, and poor spatial resolution. These limitations may be easily overcome by the use of x-ray tomographic imaging, which allows for highly accurate imaging of the internal features of an object in a non-destructive fashion. This thesis describes in detail the design of a GUI based interactive cotton contaminant analysis tool. Through the use of an x-ray microtomographic scanner and image processing algorithms, it is shown that x-ray tomographic imaging can provide very accurate information regarding shape, size, and density of cotton contaminants. This information has been analyzed using a fuzzy-logic-based classification scheme to create a highly accurate contaminant analysis tool. Despite its obvious advantages, x-ray imaging does have some drawbacks, principle among which pertains to the time taken to perform the procedure. These drawbacks, along with possible solutions have also been discussed in this thesis. It is our firm belief, however, that if realized in real-time, this procedure will have a definite impact on the cotton cleaning process, and indeed on the economic value of cotton.

Degree

thesis:*
Name thesis:degree_name
M.S.E.E.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Educational Psychology
Department thesis:degree_department
Educational Psychology
Grantor dc:publisher
Texas Tech University
Year dc:date.issued
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pai, Ajay S

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Unrestricted.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2346/11201

Chain of custody

source
Harvested from
Texas Technology University
Base URL
ttu-ir.tdl.org/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Pai, Ajay S. X-ray microtomographic image analysis for identification of cotton contaminants. Masters thesis, Texas Tech University, 2002. https://hdl.handle.net/2346/11201