Texas Tech University
Methane detection by He-Ne laser for oil and natural gas prospecting
Abstract
dc:description.abstractSurface geochemistry studies are valuable methods of petroleum prospecting. Atmospheric methane surveys can outline those areas where detailed geochemical studies need to be conducted. This report describes a field device capable of measuring small changes in methane concentration in the near surface atmosphere. Methane concentration is determined by measuring the attenuation of the 3.3922y He-Ne line in a pressurized gas flow cell due to absorption by methane. A second He-Ne laser line at 3.3912 p, which is only weakly absorbed by methane, is used as a reference signal to compensate for laser intensity fluctuations and scattering by water and dust. This system s fast, allowing measurements to be made from a moving vehicle- Also, the system allows for continuous sampling of the changing methane concentration as opposed to point measurements.
Degree
thesis:*- Name thesis:degree_name
- M.S.
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Physics
- Department thesis:degree_department
- Physics
- Grantor dc:publisher
- Texas Tech University
- Year dc:date.issued
- 1984
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Jordan, Kevin James
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- Unrestricted.
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2346/14743