Back to search

Texas Tech University

An experimental method to measure the porosity from cuttings: Evaluation and error analysis

Abstract

dc:description.abstract

As an economical approach to formation evaluation, drill cutting analysis provides significant information on petrophysical parameters which help us to understand the reservoir behavior. Researchers are gradually paying more attention to the study of drill cutting samples which potentially promote and enrich the reservoir characterization process. This thesis project concentrates on measuring the porosity from cuttings. An evaluation of the improved method is presented by comparing porosity data estimated from artificial cuttings with various sizes to the reference value measured from core samples. Since the estimation of bulk volume is not practically possible for cutting samples, the measurement of porosity from cuttings depends on the grain volume Vg and the pore volume Vp. According to the procedure presented by IFP, the volume of grain is calculated from the weight of dried cuttings applying an average grain density. As an improved point, we will use more accurate values of grain density which obtained from conventional core analysis for measuring cuttings porosity. Additionally, the pore volume is calculated by using a saturation method adapted to cuttings. The cuttings are obtained from crushed cores with different permeabilities and screened into four different sizes. The analysis of results shows that estimating the porosity from cuttings by using the proposed method is effective and reasonable. There is a close relationship between the results and the size of cuttings. After removing excess liquid between cuttings, the measured porosity from all cutting sizes is overestimated. Cuttings with the smallest size A (0.425-0.85 mm) show the greatest deviation. For cuttings with larger size, the measured porosity ranges smaller over time compared with that from cuttings of smaller size. We use one hour as the optimum desaturation time which corresponds to the measured results. The largest size D (2.8-4.0 mm) gave the best results that generated the minimum error. We also discussed the influence of permeability on the results.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Petroleum Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Petroleum Engineering
Department thesis:degree_department
Petroleum Engineering
Grantor
Texas Tech University
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yu, Yang
Chair dc:contributor.committeechair
  • Menouar, Habib K.
Committee members dc:contributor.committeemember
  • Heinze, Lloyd R.
  • Sheng, James J.

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Other
2346/ETD-TTU-2013-05-1010

Chain of custody

source
Harvested from
Texas Technology University
Base URL
ttu-ir.tdl.org/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Yu, Yang. An experimental method to measure the porosity from cuttings: Evaluation and error analysis. Masters thesis, Texas Tech University, 2013. https://hdl.handle.net/2346/48848