Back to search

Texas Tech University

Ammonia-nitrogen removal from feedlot lagoon effluent by algae system

Abstract

dc:description.abstract

A cattle feedlot lagoon effluent was used in both a batch and continuous flow system to determine the capability of an algae species, P. bohneri^ to remove ammonia-nitrogen fi-om the effluent. In the batch reactors containing P. bohneri, an initial ammonia-nitrogen concentration of 66 mg/L was reduced to below 0.5 mg/L within 3 days. The initial chlorophyll-a concentration of 500 ng/L increased to 2,000 ng/L within 6 days. In the continuous flow non-baffled reactor, the influent ammonia-nitrogen of 70 mg/L decreased to below 0.3 mg/L at the hydraulic retention time (HRT) of 4 days. In the continuous flow baffled reactor, the effluent ammonia-nitrogen concentration was 0.1 mg/L at the HRT of 4 days. In both the non-baffled and baffled reactors, the ammonia-nitrogen concentrations in the effluent were below 0.1 mg/L at the HRTs of 8 and 12 days. The non-baffled reactor had the maximum chlorophyll-a concentration of 4,153 |ig/L at the HRT of 12 days, while the highest chlorophyll-a concentration in the baffled reactor was 2,695 |ig/L at the HRT of 8 days. The non-baffled reactor had the highest nitrogen utilization rate (3.68 mg/L-day) by the P. bohneri culture at the HRT of 8 days. The baffles in the continuous flow system contributed to the lower effluent substrate concentration, but caused the rapid cell wash-out. Therefore, the cell production in the baffled reactor was lower than that in the non-baffled reactor. The algae production and the substrate removal models were developed on the basis of the relationship between microbial growth, substrate utilization, and a finite volume occupied by microbes. In the batch reactor study, the equation of predicted algal production fit measured data with an R value of 0.86 and was highly significant (a = 0.001). For the ammonia-nitrogen removal by the P. bohneri culture, the measured versus predicted resuhs were highly significant (a = 0.001) with an R^ value of 0.98. In the continuous flow, non-baffled reactor, the developed model predicted measured algal cell concentration with respect to hydraulic retention time with an R^ of 0.98 (a = 0.01). The experimental data and predicted results for the specific nitrogen utilization rate by P. bohneri agreed well (R^ = 0.94, a = 0.01) in the continuous flow, non-baffled system.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department thesis:degree_department
Civil Engineering
Grantor
Texas Tech University
Year dc:date.issued
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ahn, Seyoung
Committee members dc:contributor.committeemember
  • Parker, Nick C.
  • Ramsey, Ralph H.
  • Gregory, James M.
  • Mollhagen, Tony Ray
  • Moorhead, Daryl L.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Unrestricted.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2346/61319

Chain of custody

source
Harvested from
Texas Technology University
Base URL
ttu-ir.tdl.org/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Ahn, Seyoung. Ammonia-nitrogen removal from feedlot lagoon effluent by algae system. Doctoral thesis, Texas Tech University, 1996. https://hdl.handle.net/2346/61319