Texas Tech University
Accounting for parameter uncertainties in the prediction of porous femoral stem reliability
Abstract
dc:description.abstractThe increase in elderly population and the increasing number of young adults undergoing hip replacement surgery makes the reliability of femoral stems very important. Revision surgery due to aseptic loosening is one the most common reason for early failure. Aseptic loosening is reported to occur mainly due to stress shielding. Revision surgery can greatly hamper the standard and quality of life of those affected. To improve the reliability of the porous femoral stems, a probabilistic analysis has been performed on porous femoral stem designs incorporating different cubic lattice structures. The design and manufacturing of femoral stems have many uncertainties in its material properties, loading, geometry, environment of operation and manufacturing errors. However, reliability analysis done on current designs which try to address the stress shielding problem, is performed deterministically. This research seeks to answer the research question can probabilistic analysis be used to enhance reliability analysis of porous hip stem designs which incorporate either stretch or bend dominated lattices? The specific aims of the research are to develop a probabilistic risk-based analysis framework to perform probabilistic analysis on a porous stem incorporating bend dominated lattice and to perform probabilistic analysis on a porous stem incorporating stretch dominated lattice. The loading and design parameters were considered as random variables and their uncertainties quantified using maximum entropy principle. The probabilistic analysis of the performance functions: stem stiffness, surface-to-volume-ratio (SV) and strength-to-stiffness-ratio (SS) of porous femoral stems was carried out. The probability of failure of different designs were calculated. This study helps in revealing the performance and reliability of various stem models and can help the designer to propose the stem with best performance for surgery.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department thesis:degree_department
- Mechanical Engineering
- Grantor
- Texas Tech University
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wanki, Godlove Azhie-Nwi
- Chair dc:contributor.committeechair
-
- Ekwaro-Osire, Stephen
- Committee members dc:contributor.committeemember
-
- Aksak, Burak
- Tan, George
- Yang, James
- Yeo, Changdong
Subjects
dc:subject × 2Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- Unrestricted.
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2346/85576