Abstract
dc:description.abstractThe world was forced into a lockdown in March 2020 due to the exponential spread of severe acute respiratory syndrome related coronavirus 2 (SARS-CoV-2) causing the 2019 coronavirus disease (COVID-19) in humans. COVID-19 was declared a pandemic within a short span of four months indicating the rapid rate of spreading. Such a fast and global spread had to be curtailed to thwart further spread apart from identifying, isolating, and treating the infected. For screening the affected individuals, diagnostic tests were the only route. However, during the initial phase of the pandemic, polymerase chain reaction (PCR) based techniques being the gold standard were the only means for diagnosis. The turnaround time for test results was about 5 days. Such a long-time delay meant the infection could spread to more people from the affected individual in the meanwhile. Therefore, alternate tests that could satiate the high and rapid testing demand became the need of the hour. Several alternate techniques targeting the antigen instead of nucleic acid information sprung to minimize the turnaround time from days to hours and minutes. Later flow and immunoassays found prevalence for their quick turnaround time and ease of use. A number of at-home kits based off these techniques also arrived shortly after. Nevertheless, they did compromise on accuracy for speed. A different class of diagnostic sensors called electrochemical sensors started gathering attention for their quick turnaround time, ease-of-operation, miniaturization, and point-of-use applications. Typical electrochemical pathogen sensors have a biorecognition element immobilized onto their electrode surface for detection with improved sensitivity and specificity. Electrochemical sensing also showed promise to scale up and meet the testing demand. However, one serious obstacle to commercializing these sensors was in reproducing the activity of sensors between batches. Differences in immobilization uniformity caused huge variability in these sensors. Being heavily reliant on the biorecognition element, the sensing was at times jeopardized due to inactivation under harsh field conditions. Often, this led to a drop in accuracy of sensor resulting from false results. To overcome such shortcomings, this dissertation focused on the invention and development of an electrochemical sensor for ultrafast COVID-19 (UFC-19) diagnosis. The uniqueness of this sensor was in its capability to generate an electrocatalyst in-situ, prior to each test, and interact with the SARS-CoV-2 viral proteins in the sample during the process. The sensing time for this sensor was less than a minute owing to the quick interaction between the electrode and the analyte. Another advantage of the sensor was the use of saliva as sample instead of invasive sampling involving nasopharyngeal swab or drawing blood or serum. However, the detection mechanism for such a contemporary sensor was unclear and had to be explored in detail. To this end, the effect of different operating conditions was studied to understand the kinetic and mass transport limitations. Characterizing the reactions electrochemically facilitated the calculation of critical parameters and subsequently propose the detection mechanism. Additionally, the importance of hydroxide ion changes and nickel electrochemical oxidation for detecting SARS-CoV-2 have been established with evidence and discussed in detail.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Chemical Engineering
- Department thesis:degree_department
- Chemical Engineering
- Grantor
- Texas Tech University
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ramanujam, Ashwin
- Chair dc:contributor.committeechair
-
- Botte, Gerardine G.
- Committee members dc:contributor.committeemember
-
- Almodovar, Sharilyn
- Pastora, Jenifer G.
- Lu, Qiugang
Subjects
dc:subject × 7Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- Access is not restricted.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2346/97307