Back to search

Texas Woman's University

Whole-body vibration: Is gravitational force a valid measurement of exercise intensity?

Abstract

dc:description.abstract

The primary aim of the whole-body vibration (WBV) investigation was to determine if g-force is a valid measurement of vibration exercise intensity (VEI). For this purpose, twelve healthy lean adults (male, 7; female 5; age, 29.4 ± 6.4 years; height 171.4 ± 4.9 cm; weight, 67.4 ± 10.4 kg; BMI, 22.9 ± 2.6 kg/m2) voluntarily participated for the study. To examine the relationship between g-force and VEI, a 3-way (4-muscle group x 4-frequency x 2-amplitude) repeated measures design was employed, which analyzed electromyography (EMG) muscle activity in the vastus lateralis (V.L.), vastus inedialis (V.M.), gastrocnemius lateralis (G.L.) and gastrocnemius medialis (G.M.) muscles during WBV exercise. Participants, performed a standard unloaded isometric high-squat position (knee angle 30 degrees, hip angle 30 degrees, feet [middle toe to middle toe] 30cm apart) while at eight different levels (k = 8) of g-force. The levels of g-force were derived from four different preset frequency settings (30, 35, 40, and 50 Hz) measured at both the low and high amplitude settings. Each participant underwent four trials at each of the amplitudes. In each trial a participant experienced all four preset frequencies and a control condition. The VEI was operationally defined as the WBV-induced percent increase in EMGrms compared with the control condition (no vibration). Control data was expressed as a percent of maximum voluntary contraction (MVC), thus allowing for inter-subject comparisons. The results of the study clearly indicated that the highest g-forces were not associated with the highest VEI responses. The highest VEI responses were found at the lower frequencies (30 and 35 Hz) with exception of the G.M. (40 Hz). Furthermore the higher amplitude produced an approximately 35% higher VEI response than the low amplitude. Based on the findings it was concluded that g-force is not a valid measurement of VET. Additionally, the study revealed that both a large degree of inter-subject variability in VET responses exists and that WBV only produces a small amount of muscle activity when expressed relative to MVC data. Thus, it was concluded that WBV should only be used as a supplement to traditional exercise prescription, not as a replacement.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Department thesis:degree_department
Kinesiology
Grantor
Texas Woman's University
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Robinson, Christopher J.
Chair dc:contributor.committeechair
  • Ben-Ezra, Victor
Committee members dc:contributor.committeemember
  • Davis, Ron
  • Marshall, David

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/11274/10693

Chain of custody

source
Harvested from
Texas Woman's University
Base URL
twu-ir.tdl.org/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Robinson, Christopher J.. Whole-body vibration: Is gravitational force a valid measurement of exercise intensity?. Doctoral thesis, Texas Woman's University, 2010. https://hdl.handle.net/11274/10693