Texas Woman's University
Evaluating the long term performance of hospital replacement mattresses
Abstract
dc:description.abstractThis study focused on evaluating pressure relieving properties of five hospital replacement mattresses utilized in a hospital in the Texas Medical Center in Houston. The Mini-Texas Interface Pressure Evaluator was used to monitor pressure in mmHg at the interface between a bowling ball and the mattresses at three locations. Data were reported in three timed intervals. A one-way ANOVA with and without repeated measures revealed significant differences in magnitude of pressures (p = 0.02) at the 30 cm and 100 cm locations (p = 0.01). Minimal pressure changes occurred over time for all sections of the mattress; however changes were not significant.
Degree
thesis:*- Name thesis:degree_name
- Master of Arts
- Level thesis:degree_level
- Master
- Discipline thesis:degree_discipline
- Occupational Therapy
- Department dc:contributor.department
- Occupational Therapy
- Grantor
- Texas Woman's University
- Year dc:date.issued
- 1993
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Callaghan, Rosemary
- Committee members dc:contributor.committeemember
-
- Garner, Susan
- Kouskop, Thomas
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/11274/14775