Back to search

University of British Columbia

Seismic response of diagonally reinforced slender coupling beams

Abstract

dc:description

The seismic response of diagonally reinforced slender coupling beams is investigated. Primarily, a typical coupling beam found in high-rise buildings in the Vancouver area is studied. Compared to past experiments, this study takes into account a new variable, the axial restraint given by the concrete slab surrounding the coupling beam. Desirable and ductile properties of the beam are studied throughout this work, such as ductility capacity, stiffness degradation, overstrength and energy dissipation capability. A finite element analysis was performed to study the axial restraint parameter mentioned above and assess the degree of restraint given by the slab to the coupling beam. Parameters such as the slab dimensions, slab pre-cracking, slab thickness, mesh size of the model and tension stiffening model are considered. This analysis indicated that the tension stiffening model used for the concrete is the most important parameter. A full-scale coupling beam specimen was tested to develop an analytical model and compare the results with well-known formulas recommended by various Codes. The specimen represented a typical coupling beam found in high-rise buildings in the Vancouver area. The specimen was subjected to cyclic loading and Dywidag bars were provided to model the slab axial restraint. The results showed higher overstrength and stiffness degradation factors than the ones expected from well-known formulas. As expected for diagonally reinforced coupling beams, the specimen showed good ductility and energy dissipation properties. An analytical model based on a truss structure was developed to better understand the behaviour of diagonally reinforced coupling beams. The model gave insight to main factors of the problem, such as diagonal reinforcement, geometry, concrete considered and slab restraint. The monotonic prediction of the model was reasonably similar to the envelope given by the experimental results. Expressions were developed from this model to predict the cracked stiffness and overstrength factor.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gonzalez, Emilio

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/11532

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Gonzalez, Emilio. Seismic response of diagonally reinforced slender coupling beams. master's thesis, University of British Columbia, 2001. http://hdl.handle.net/2429/11532