Experimental investigation of boiling heat transfer to R-134a refrigerant

Abstract

dc:description

The aim of the present investigation was to improve the understanding of the boiling heat transfer to alternative refrigerants, specifically to tetrafluoroethane (R-134a). The refrigerants are mainly used in heat transfer applications, and due to environmental limitations, a need for assessing the suitability from a heat transfer efficiency perspective of new candidates has become a priority. The heat transfer coefficient that mainly controls the heat transfer phenomenon is very dependent on the operating conditions and on the geometry of the equipment and therefore an experimental assessments of proposed alternative refrigerants are required. In order to evaluate the performance of R-134a, a significant part of the project consisted in designing and building an experimental apparatus for the heat transfer study. A closed circulation loop with heat transfer and hydraulic equipment was constructed. The apparatus was equipped with state of art instrumentation, control and data acquisition equipment. Further, subcooled boiling experiments were pursued. These were carried out based on an experimental strategy that led to a significant amount of data, limited only by the maximum mass flow rate that could be achieved. Saturated boiling experiments that followed generated a limited data bank due to technical factors. For assessing the results, several theoretical methods for predicting the heat transfer coefficient were employed. Chen's (1966) correlation was used for both subcooled and saturated boiling data validation. A different method of extending Chen's correlation to subcooled boiling, when used for verifying experimental data was proposed. Liu and Winterton (1997) and Gungor and Winterton (1986 and 1987) correlations were also employed for validating the experimental data. This exercise confirmed that the measured vs. calculated heat transfer coefficients were within the range of accuracy claimed by correlations authors and/or acceptable from an engineering perspective. Discussions and conclusions for both subcooled and saturated boiling were part of the data analysis.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Podut, Alexandru Ion

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/12199

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Podut, Alexandru Ion. Experimental investigation of boiling heat transfer to R-134a refrigerant. master's thesis, University of British Columbia, 2002. http://hdl.handle.net/2429/12199