Back to search

University of British Columbia

Improved interface for deep venous thrombosis screening using B-mode ultrasound

Abstract

dc:description

This work presents a system for the screening of deep venous thrombosis by processing B-mode ultrasound images, and by using information from additional force-torque and location sensors. It is known that deep venous thrombosis (DVT) is a disease that affects the venous system, where blood clots are formed and obstruct the venous pathways, causing serious consequences such as pulmonary embolism. Identifying DVT using conventional ultrasound principally relies on identifying incompressible veins which contain clots by using the B-mode imaging modality to view vessels in a transverse plane. A model-based contour detection method is presented which assumes that the transverse section of a vein can be described by an ellipse. By using the image brightness values a modified Star-Kalman filter is used to detect the vessel contour, and a validation scheme is implemented in order to accept or reject the detected curve. Additional information from a six degree-of-freedom force-torque sensor and a six degree-of-freedom location sensor allow the ultrasound image and detected contour to be placed in a three-dimensional virtual environment, were they are displayed in correct perspective. By stitching together several detected contours, a three-dimensional model of the examined vessel can be constructed and displayed. The force-torque information is combined with the vessel area obtained via the contour detection method, and an objective compression assessment can be obtained for the examined vessel segment. By repeating this procedure, a complete vessel can be screened for DVT, with an objective measure as a result. Additionally, this information can be mapped to the previously constructed virtual model.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Guerrero, Julian

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/14004

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Guerrero, Julian. Improved interface for deep venous thrombosis screening using B-mode ultrasound. master's thesis, University of British Columbia, 2002. http://hdl.handle.net/2429/14004