Back to search

University of British Columbia

Quantitative evaluation of metal artifact reduction techniques in MRI

Abstract

dc:description

Several techniques for metal artifact reduction in MRI were studied in order to determine their effectiveness. The noise and blur introduced by the techniques were also investigated. To this end, non-metallic replicas of two metal implants (stainless steel and titanium/chromium-cobalt femoral prostheses) were fabricated from wax, and MR images were obtained of each component immersed in water. The difference between the images of each metal prosthesis and its wax replica was measured in terms of energy. The difference energy attributed to noise and blur were isolated, resulting in a measure of the metal artifact. This new "gold standard" method was successfully demonstrated to provide a quantitative means of measuring metal artifact. Several pulse sequences were evaluated in terms of metal artifact reduction capability, as well as signal-to-noise ratio and blur. The analysis revealed that increasing the image bandwidth from ±16 kHz to ±64 kHz reduced metal artifact by an average of 60%, while employing View Angle Tilting (VAT) was only slightly more efficient, reducing metal artifact by an average of 63%. The metal artifact reduction sequence (MARS), which combines the increased image bandwidth with VAT as well as an increased slice-select bandwidth, resulted in the least amount of image distortion, reducing the artifact by an average of 79%. The signal-to-noise ratio was lower for MARS, but blurring was found to be significantly improved.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kolind, Shannon Heather

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/14574

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kolind, Shannon Heather. Quantitative evaluation of metal artifact reduction techniques in MRI. master's thesis, University of British Columbia, 2003. http://hdl.handle.net/2429/14574