Back to search

University of British Columbia

Wide band electro-optic intensity modulator frequency response measurement using optical heterodyne, Down-conversation Technique

Abstract

dc:description

In this thesis a novel system for measuring the frequency responses of electrooptic intensity modulators in the millimeter-wave regime is described. As the frequency responses of modulators increase, wide band, and cost effective methods to measure these responses need to be developed. The system described in this thesis uses optical heterodyning and a wide band photodiode to generate millimeter-waves to drive the device under test (DUT). The need for a wide band microwave sweeper can therefore be eliminated. Moreover, an inexpensive frequency shifter consisting of a Mach-Zehnder modulator and an optical bandpass filter is used to down-convert the output of the DUT to a low microwave frequency at which the output is easily measured. The system measures | S₂₁ | in dBe. The system can measure the frequency responses of different types of electrooptic intensity modulators such as Mach-Zehnder modulators, mode-converter modulators, electro-optic polymer modulators, and should also work for electroabsorption modulators. In this thesis, the frequency response measurement system is described, and mathematical expressions for the optical fields at the output of an electro-optic modulator are developed when the DUT is biased or operated at its maximum, quadrature, and minimum points. High frequency measurements on a 10 Gb/s LiNbO₃ Mach-Zehnder type modulator and a 40 Gb/s GaAs mode-converter type modulator are made. The measurements show close agreement with | S₂₁ | measurements made using vector network analyzers and calibrated wide band photodiodes. In addition, the harmonic rejection feature of our system is described. Our system "rejects" higher order harmonics, due to the non-linearities, generated in the DUT with proper selection of the modulation and the shift frequencies. This feature means that our system can measure the linear frequency response of the DUT even if it is operated, or biased, in a non-linear region.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lam, Alfred Kan Min

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/16552

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Lam, Alfred Kan Min. Wide band electro-optic intensity modulator frequency response measurement using optical heterodyne, Down-conversation Technique. master's thesis, University of British Columbia, 2005. http://hdl.handle.net/2429/16552