Back to search

University of British Columbia

Meshing and rendering of patient-specific deformation models with application to needle insertion simulation

Abstract

dc:description

Tissue deformation is common during many medical interventions. An accurate simulation of these procedures necessitates accounting for tissue displacements by modeling tissue deformation and medical tool interaction. In minimally-invasive procedures, due to lack of visibility, physicians rely on haptic feedback and medical imaging to assess the immediate anatomical configuration and relative medical tool position. These procedures are often difficult to learn and therefore extensive training becomes essential. Computerized training systems offer an alternative to cadavers and training on patients. To accurately model the tissue deformation, most such systems require a mesh representation of the anatomy. To replicate the medical imaging feedback offered during procedures, a realistic image simulation approach is also needed. In this thesis, a novel energy-based meshing technique taking medical images and producing desirable meshes for the finite element method is introduced. This method employs an image-based discretization energy combined with a geometry-based element quality energy. The former promotes each mesh element to cover similar intensity image regions, while the latter ensures the element suitability for finite element simulation. A method that can mimic realistic B-mode ultrasound images under deformation is also presented in this thesis. This method first maps the pixels of an image from a deformed mesh configuration back to the nominal configuration, and then interpolates them in a B-mode voxel volume reconstructed a priori. Needle insertion is involved in several medical procedures. These percutaneous procedures will benefit significantly from advances in simulating needle-tissue interaction, for which a 3D model is proposed in this thesis. Simulating needle flexibility is achieved fast and accurately using a novel approach employing torsional springs. The needle insertion simulation with haptic feedback is presented for a training scenario for prostate brachytherapy, where simulated ultrasound images coupled with deformation are also displayed. A scheme to generate patient models for this system is also devised using both the conventional meshing techniques in the literature and the proposed variational meshing method.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Goksel, Orcun

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/17418

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Goksel, Orcun. Meshing and rendering of patient-specific deformation models with application to needle insertion simulation. doctoral thesis, University of British Columbia, 2009. http://hdl.handle.net/2429/17418