Abstract

dc:description

Volatile organic compounds (VOCs) are a precursor to the formation of ground-level ozone and airborne particulate matter, both of which are hazardous to human health. Currently in Canada, other air pollutants such as ozone and nitrous oxides are measured by an air quality monitoring network in real-time, while VOCs are collected in canisters and sent to a central laboratory for analysis. This is a time-consuming and non real-time method, and due to the spatial variability of air pollution, many points of measurement are needed. A distributed point sensor network could address the resolution and real-time challenges, but would impose an added operating expenditure burden on air quality monitoring agencies. Low-cost, yet sensitive chemical sensors could contribute to lowering operating expenditures of a network’s sensing units over the installed lifetime of the units. The objective of this work was to lay the groundwork for a sensing platform from which low-cost yet sensitive chemical sensors can be developed. The sensing platform is an all-polymer surface acoustic wave (SAW) device, and the materials selected for its fabrication are Polyvinylidene Fluoride (PVDF) for the sensor substrate and Poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) for the interdigital transducer electrodes. In this work, an apparatus and a process for preparing piezoelectric PVDF film was developed. PVDF-based resonators were successfully demonstrated. In addition, repeatable processes for inkjet micropatterning highly electrically conductive PEDOT:PSS electrode tracks on PVDF were developed for three inkjet nozzle orifice sizes (20, 30, 40 µm). For tracks micropatterned using the same process, the electrical resistances have a standard deviation of 8.5% of the average. The electrical conductivity of micropatterned tracks is approximately 150 S/cm, or one-sixth of the manufacturer’s claimed bulk film conductivity. Using the 30 µm nozzle, the smallest electrode track width that can be micropatterned repeatably is 75 µm. A track width of 55 µm was achieved using the 20 µm nozzle.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Man, Gabriel

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-ShareAlike 3.0 Unported
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/17469

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Man, Gabriel. Towards all-polymer surface acoustic wave chemical sensors for air quality monitoring. master's thesis, University of British Columbia, 2009. http://hdl.handle.net/2429/17469