Back to search

University of British Columbia

Study of wedged asymmetric photon beams

Abstract

dc:description

In radiation therapy, many recent advances have been made in the technology used for dose delivery. However, conventional physical wedges are still in clinical use. The combination of asymmetric field collimation and physical wedge presents a challenge for accurate dose calculation. Algorithms for calculating monitor units (MUs) in wedged asymmetric photon beams as implemented in treatment planning systems have their limitations. In this work, the dose calculations for rectangular wedged asymmetric fields by the Eclipse treatment planning system were tested by direct comparison to ion chamber measurements and up to 6.5% discrepancy was found. Monte Carlo simulation by BEAMnrc was used for independent dose calculations. Finally, a correction method was developed for accurate wedged asymmetric dose calculations. The difference in dose between a wedged asymmetric field and the corresponding wedged symmetric field is accounted for by a correction factor that is a function of field sizes, off axis distance and depth of measurement. For both 6MV and 18MV photon beams at d max [subscript] and 10cm, the correction factor is within 1% of the measurement in most cases and the maximum difference is 2%. The dose at the asymmetric field center, which is based on wedged symmetric profiles and the correction factor, is within 2% of the measured dose in most cases and the maximum difference is 4%. It can be concluded that our simple correction factor is able to calculate dose at the center of wedged asymmetric fields with acceptable accuracy.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Qiu, Yue

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/18097

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Qiu, Yue. Study of wedged asymmetric photon beams. master's thesis, University of British Columbia, 2006. http://hdl.handle.net/2429/18097