The determination of effective thicknesses from transmission measurements with gamma rays

Abstract

dc:description

The usual starting-point for clinical dosimetry is the dose distribution due to a radiation beam in a homogeneous medium like water. The modification of the standard distribution for the case of an inho-mogeneous medium (patient) requires detailed information about internal structures. For heavy charged particle beams and for photon beams of high enough energy, the single parameter which most nearly determines the penetration of the radiation is the electron density (electrons/ cm³). The integrated electron density along a path (electrons/cm²) is uniquely related to the narrow-beam γ-ray transmission along that path. Hence, a measurement of γ-ray transmission should provide useful information. This work describes a new technique for performing these measurements. We have used a ⁶⁰Co therapy source with a rectangular field long enough in one direction to span the width of a human cross section and narrow in the other direction to minimize the effects of scattered radiation. Rather than collimate our detectors, we have devised a simple mathematical procedure to calculate the scatter contribution at each point of interest along the width of the radiation field. Narrow-beam transmission values can then be evaluated from the original measurements by simple substraction of this scatter contribution. An ionization chamber, because of its energy independence and accuracy, was used to acquire the basic transmission data. X-ray film and silicon diodes, because of their superior resolution and response speed, were selected for the measurements performed with an inhomogeneous phantom. The energy dependence of the latter dosimeters has not been a drawback when used in the experimental conditions described here. The method thus permits that rapid transmission measurements be performed along various paths of a transverse cross section. When tested with an inhomogeneous phantom, the accuracy obtained compares favourably with published values using collimated detectors. Information obtained by this method is directly applicable to the dosimetry of treatments performed with photon beams of energy greater than 0.6 MeV and heavy charged particle beams like protons and π⁻ mesons.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
1975

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Goulet, Pierre

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/19378

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Goulet, Pierre. The determination of effective thicknesses from transmission measurements with gamma rays. master's thesis, University of British Columbia, 1975. http://hdl.handle.net/2429/19378