Abstract

dc:description

The effect of a drag-reducing long-chain polymeric additive on the structure of wall turbulence in pipe flow was investigated experimentally. The system studied was a 50 wppm polyacrylamide-water in a 2.63 cm diameter pipe. Due to the anomalous behaviour of conventional turbulence probes in drag-reducing flows, a nondisturbing optical technique was developed. Real-time holographic interferometry was used for flow visualization and turbulence measurements. An interference fringe pattern generated by the holographic method was superimposed on a region of the pipe wall. The real-time modulation of these fringes by a refractive index enhancer infused into the flow at the wall was recorded by medium-speed motion photography. Spatial and temporal correlations of concentration fluctuations and intensity measurements during turbulent flow were obtained from motion pictures. Both spanwise and normal directions to the wall were observed to investigate 'streaks' and 'bursts' that originate in the wall-layer flow. Measurements of gross flow, spanwise streak spacing, burst frequency and sublayer period were obtained in addition to visual impressions of the flow. The drag-reducing Separan AP30 solution flows appeared physically different from the water flows when comparison was made at either equal flow rate or equal wall shear velocity. Measurements showed that the drag-reducing additive increased both the physical and non-dimensional spanwise streak spacing. The additive also drastically reduced the rate of bursting. The time interval between bursts, computed using the model of Kim-Kline-Reynolds, was almost equal in both drag-reducing and water flows when compared at equal wall shear. Direct measurements of streak lifetime using wall layer concentration autocorrelations showed the drag-reducing sublayer to have a longer lifetime than that of water at the same wall shear. The drag-reducing sublayer period increased over the Newtonian value by a factor almost equal to the ratio of the non-dimensional streak spacing during drag reduction to the corresponding wall shear Newtonian value. These results suggest a stabilized wall layer in the polymeric solution flow as compared to that of the Newtonian solvent, resulting in lesser turbulence production and reduced frictional drag. The role of elongational viscosity of the dilute polymer solution is discussed as a possible mechanism to explain the visualized and measured phenomena.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemical and Biological Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1975

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Achia, B. Umesh

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/19500

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Achia, B. Umesh. Structure of pipe wall turbulence in Newtonian and drag-reducing flow : a hologram-interferometric study. doctoral thesis, University of British Columbia, 1975. http://hdl.handle.net/2429/19500