University of British Columbia
Electronic data acquisition system for the energy balance/Bowen ratio measurement of evaporation
Abstract
dc:descriptionA system for the energy balance/Bowen ratio measurement of evaporation was designed and tested. The system produces eight channels of integrated meteorological data for evaporation calculation. The various voltages required to operate the meteorological sensors are produced internally by a bank of regulated power supplies. Control signals are generated by a quartz crystal -clock. The data in a selected channel and the time of day are displayed on the front panel of the data logger. All eight channels of data and the time are printed on a paper tape every 15 or 30 minutes as desired. The output circuitry was designed to be compatible with microprocessor components. The data logger is contained in a 60 cm x 50 cm x 40 cm metal cabinet and is powered by 110 VAC. The laboratory and field tests of the system were successful.
Degree
thesis:*- Name thesis:degree_name
- Master of Science - MSc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Soil Science
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 1976
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tang, Paul Wing Kay
Rights
dc:rights- Statement dc:rights
-
- For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/19869