Abstract
dc:descriptionThe effects of iron fouling on the steady and unsteady state electrodialysis processes were studied. Both processes were compared on a bench scale, under the same operating conditions of voltage (20 and 30 volts), fluid velocity (1.25 cm/sec), and iron (II) concentration in their feed streams (0, 1, and 5 ppm). A 2000 mg./l. sodium chloride solution containing Fe?? as ferrous chloride was circulated through the process for 20 hours. The amount of deposition on a test pair of membranes was determined and compared to the change in separation factor over the run. The power consumption per litre per cell was determined for both processes and found to be a function of dialysate concentration. Due to limitations in the power supply, the limiting current I lim could not be used as a fouling parameter, and the deposition of iron was measured instead. The separation factor in both processes decreased with the amount of iron accumulated on the membranes, while the polarized cell resistance remained relatively unchanged. This is in agreement with the "sandwich membrane model".
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science - MASc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Chemical and Biological Engineering
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 1981
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tremblay, André-Yves
Rights
dc:rights- Statement dc:rights
-
- For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/22832