Back to search

University of British Columbia

Towards a novel minimally invasive three dimensional ultrasound imaging based computer assisted orthopaedic surgery system for bone fracture reduction

Abstract

dc:description

Current practice in orthopaedic surgery relies on intra-operative two dimensional (2D) fluoroscopy as the main imaging modality for localization and visualization of bone tissue, fractures, implants, and surgical tool positions. However, with such projection imaging, surgeons typically face considerable difficulties in accurately localizing bone fragments in three dimensional (3D) space and assessing the adequacy and accuracy of reduced fractures. Furthermore, fluoroscopy involves significant radiation exposure. Ultrasound (US) has recently emerged as a potential non-ionizing imaging alternative that promises safer operation while remaining relatively cheap and widely available. US image data, however, is typically characterized by high levels of speckle noise, reverberation, anisotropy and signal dropout which introduce significant difficulties in interpretation of captured data, automatic detection and segmentation of image features and accurate localization of imaged bone surfaces. In this thesis we propose a novel technique for automatic bone surface and surgical tool localization in US that employs local phase image information to derive symmetry-based features corresponding to tissue/bone or tissue/surgical tool interfaces through the use of 2D Log-Gabor filters. We extend the proposed method to 3D in order to take advantage of correlations between adjacent images. We validate the performance of the proposed approach quantitatively using realistic phantom and in-vitro experiments as well as qualitatively on in-vivo and ex-vivo data. Furthermore, we evaluate the ability of the proposed method in detecting gaps between fractured bone fragments. The current study is therefore the first to show that bone surfaces, surgical tools and fractures can be accurately localized using local phase features computed directly from 3D ultrasound image volumes. Log-Gabor filters have a strong dependence on the chosen filter parameters, the values of which significantly affect the outcome of the features being extracted. We present a novel method for contextual parameter selection that is autonomously adaptive to image content. Finally, we investigate the hypothesis that 3D US can be used to detect fractures reliably in the emergency room with three clinical studies. We believe that the results presented in this work will be invaluable for all future imaging studies with US in orthopaedics.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hacihaliloglu, Ilker

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/24463

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Hacihaliloglu, Ilker. Towards a novel minimally invasive three dimensional ultrasound imaging based computer assisted orthopaedic surgery system for bone fracture reduction. doctoral thesis, University of British Columbia, 2010. http://hdl.handle.net/2429/24463