University of British Columbia
Digital processing of somatosensory evoked potentials applied to the early diagnosis of multiple sclerosis
Abstract
dc:descriptionThis study investigated several digital techniques for the extraction of parameters from Somatosensory Evoked Potentials (SEPs). The higher frequency smaller peaks in the SEP were emphasised using a digital filter to remove the low frequency components. The filtered SEPs were compared to a Standard Wave using Dynamic Time Warping techniques which produced a Cost Function to measure abnormality. A quantification of the dispersion of the SEPs was also computed. These parameters were evaluated as to their sensitivity and reliablility when used to classify Normal and Multiple Sclerosis SEPs. They proved to be clinically significant diagnostic tools.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science - MASc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Electrical and Computer Engineering
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 1984
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Roberts, Kim Byron
Rights
dc:rights- Statement dc:rights
-
- For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/24938