Back to search

University of British Columbia

Surface density of radiant sources measured by optical microscopy : correction for diffraction and focus limitations

Abstract

dc:description

A new technique is introduced for the determination of the surface density of membrane bound components on living cells inuitro. This technique provides a simple conversion of fluorescence intensity to number density and involved the modelling of the spatial optical response of the microphotometer to account for the inherent diffraction and focus limitations of the system. A theoretical and experimental study was undertaken to examine the adsorption of a fluorescently labelled ligand (WGA) onto the membrane surface of a biological cell (the erythrocyte). WG A/red cell interaction was evaluated with a fluorescence microphometer. The microphotometer is a laser based fluorescence microscope in combination with intensified video imaging and digitizing equipment that produces fluorescence images with a resolution of 0.25μm. The fluorescence conversion technique was used to characterize the adsorption of WGA on to the red cell surface. Individual cells were isolated and incubated in various bulk concentrations of fluorescenated WGA to determine the dependence of adsorbed concentration on bulk concentration and incubation time. The equilibrium results gave a microscopic association constant of 2.95x10⁸ liters/mole, a molecular binding ratio of one WGA molecule per glycophorin molecule on the red cell surface and the number of glycophorin molecules per human red blood cell as (6.5±0.3)x10⁵.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
1986

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Knowles, David William

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/25904

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Knowles, David William. Surface density of radiant sources measured by optical microscopy : correction for diffraction and focus limitations. master's thesis, University of British Columbia, 1986. http://hdl.handle.net/2429/25904