Back to search

University of British Columbia

A laboratory and clinical study on vitreous fluorophotometry

Abstract

dc:description

The optical, electronic sensoring and data acquisition systems were assembled and the software developed for a vitreous fluorophoto-meter which was then calibrated and used to quantify the integrity of the blood-retinal barrier in a pilot study of diabetic retinopathy and multiple sclerosis compared to normal controls. Breakdown of the blood-retinal barrier was quantified by measuring fluorescence in the vitreous at standard time intervals over one hour following intravenous injection of sodium fluorescein. The plasma dye concentration was measured throughout the procedure. Leakage was expressed as a penetration ratio of the average concentration at 3mm from the retina to the total plasma dye concentration. The results from diabetic subjects showing well defined stages of retinopathy severity demonstrated the proper functioning of the instrument by showing values in approximate agreement with retinopathy severity, thus confirming the findings of previous observers. Of 16 multiple sclerosis subjects, results showed no significant difference between activity categories or level of current activity. Abnormally high penetration ratio was associated with active periphlebitis. A new finding was the presence of abnormally high leakage in 2 subjects showing no ocular signs of disease. Subjects without or with inactive periphlebitis showed breakdown of the blood-retinal barrier comparable in severity to diabetic subjects showing no or mild retinopathy. The vitreous diffusion constant of the dye for normal controls and multiple sclerosis subjects was not significantly different from that in water.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
1986

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pang, Kian Tiong

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/26022

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Pang, Kian Tiong. A laboratory and clinical study on vitreous fluorophotometry. master's thesis, University of British Columbia, 1986. http://hdl.handle.net/2429/26022