University of British Columbia
A saturation calibration of Hamamatsu’s multi-pixel photon counter
Abstract
dc:descriptionA relative calibration of the Fine-Grained Detector (FGD) in the T2K experiment is presented, with emphasis on the saturation calibration effects in Hamamatsu's multi-pixel photon counters (MPPCs). The calibration is produced on a test bed with a Hamamatsu Pico-Second Pulsed laser, on a small model of the FGD on a sample of fibers and MPPCs. The wavelength shifting fiber-MPPC complex used in the FGD is found to have an effective pixel count of 518, and to exhibit an effective after-pulsing and crosstalk fraction of 1.6% when measured between 0.6 and 0.9 Volts over-voltage (V OV).
Degree
thesis:*- Name thesis:degree_name
- Master of Science - MSc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Physics
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hastings, Simon Philip
Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/27793