Back to search

University of British Columbia

Radiative muon capture on carbon, oxygen and calcium

Abstract

dc:description

The partial branching ratio for photons of greater than 57 MeV (G[sub >57]) has been measured for radiative muon capture (RMC) on ¹²C, ¹⁶O and ⁴⁰Ca in order to determine the magnitude of the induced pseudoscalar coupling constant g[sub p] of the weak hadronic current. A time projection chamber (TPC) was used as a large solid-angle, medium-resolution pair spectrometer to detect the photons from RMC. The resulting spectra were essentially background-free, allowing a determination of the partial branching ratios to about 10% precision. For ⁴⁰Ca, the partial branching ratio obtained is in good agreement with previous measurements, and yields the value g[sub p]/g[sub a] = 5.7 ± 0.8 when compared with a phenomenological calculation of the nuclear response function and the value g[sub p]/g[sub a] = 4.6 ± 1.8 when compared with a microscopic calculation of the nuclear response function. Both of these results suggest a slight (downward) renormalization of g[sub p]/g[sub a] in ⁴⁰Ca in comparison with the value expected for a free nucleoli. For ¹⁶O, the partial branching ratio obtained in the present experiment is found to disagree strongly with one previous experiment but to agree with the second previous measurement. When compared with a phenomenological calculation of the nuclear response our result yields g[sub p]/g[sub a] = 7.3 ± 0.9, consistent with an un-renormalized value of g[sub p]. The same results compared to a microscopic calculation give the value g[sub p]/g[sub a] = 13.6 [sup +1.6]/[sub -1.9] suggesting a large (upward) renormalization of g[sub p] in the ¹⁶O nucleus. The first precise branching ratio has also been measured for RMC on ¹²C. No calculation of the nuclear response specific to ¹²C is available at present. However, when the present data are compared with a naive extrapolation of Fermi-gas model calculations of the nuclear response for heavier nuclei, the brandling ratio is found to be consistent with an unrenormalized value of g[sub p]. The present work has also provided valuable input, through the investigation of various systematic errors and potential backgrounds, into the design of a detection system for a forthcoming measurement of RMC on hydrogen.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
University of British Columbia
Year dc:date
1988

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Armstrong, David Stairs

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/29004

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Armstrong, David Stairs. Radiative muon capture on carbon, oxygen and calcium. doctoral thesis, University of British Columbia, 1988. http://hdl.handle.net/2429/29004