Back to search

University of British Columbia

Aerobic treatment of a CTMP wastewater using a rotating biological contactor

Abstract

dc:description

Effluents from high-yield TMP and CTMP mills contain biochemical oxygen demand and toxicity levels that are much higher than the effluents from low-yield kraft mills and if not properly treated before disposal can impose environmental threats to water bodies. Therefore, this study was undertaken to demonstrate the ability of a rotating biological contactor to remove organic matter from such a CTMP wastewater when operated at different flowrates and temperatures. An apparatus was constructed to allow for temperature control of the wastewater and the flexibility to change flowrates and disc rotational speed. Parameters studied included BOD₅, COD, suspended solids, dissolved oxygen, sulfur compounds, acetic acid and nutrient uptake. Because the lab device exposes a thin film of liquid to the air over an extensive surface, evaporation from the RBC as high as 87% at temperatures of ~ 30°C were experienced during the experiment. Results of this study showed that for hydraulic residence times (HRT) of 1 to 2 days the BOD₅ removal ranged from 77 to 86% with a corresponding COD removal of 63 to 72%. Increases in flowrate (decreases in HRT) resulted in a slight decrease in percent BOD (COD) removed and an increase in loading rate and BOD (COD) removal rate. An increase in temperature from 20 to 30°C increased BOD removal from 70.1 to 85% and COD removal from 45.8 to 71.4% at HRT=1.5 days. Dissolved oxygen, pH and MLVSS had no distinct effects on the removal of BOD₅ and COD. Losses due to evaporation of major volatile compounds tested were minimal at the pH of operation. Start-up time of the RBC was of the order of 1 day during the experiment. An attempt to do a run without microorganism activity by adding 50 mg/1 HgCl₂ failed to eliminate all the organisms present in the wastewater and RBC. Tracer studies revealed that the RBC was close to being perfectly mixed.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Chemical and Biological Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1991

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mathys, Renata Gabriela

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/30025

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Mathys, Renata Gabriela. Aerobic treatment of a CTMP wastewater using a rotating biological contactor. master's thesis, University of British Columbia, 1991. http://hdl.handle.net/2429/30025