Back to search

University of British Columbia

Capacitor compensation effects on the performance of synchronous machines connected to long transmission lines

Abstract

dc:description

The increase in length, size and voltages of transmission lines and the development of high voltage capacitors have revitalized interest in recent years in the study of the performance characteristics of series or shunt capacitor compensated power systems. Most of the investigations are performed, however, either on the synchronous machine or on the transmission line. Major contributions were made by Butler², Bodine³, Dineley⁵, Peterson¹⁴ and others, as outlined in chapter 1. The thesis is to develop a general analytical method for the study of the compensation problem including the effects of both the salient pole synchronous machine and the transmission line with various power factor loads connected at the receiving end. The equations for the series capacitor compensated power system with balanced load are derived in chapter 2. The transmission line is represented by a three phase nominal-T network. The transmission line equations are transformed into Park's cross field reference frame which is employed for the formulation of equations for the synchronous machine. The equations obtained can be applied to both transient and steady state analyses. Chapter 3 also studies the series capacitor compensated system except that the load is unbalanced. The equations for the study of the shunt capacitor compensated system are developed in chapter 4. Both balanced and unbalanced loads are included. Two numerical examples of practical systems are presented to illustrate the applications of the method. The synchronous machine internal voltage against load current characteristics and those of the power angle between the internal voltage and the receiving end voltage versus load current, balanced and unbalanced, at various power factor, and with different degrees of series or shunt compensation of the system are investigated. The numerical results from digital computation confirm that the series capacitor compensation is more effective than the shunt capacitor compensation and that both the series and shunt capacitor compensations increase the transmission capacity.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1966

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Conteh, Amadu Mustapha

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/37660

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Conteh, Amadu Mustapha. Capacitor compensation effects on the performance of synchronous machines connected to long transmission lines. master's thesis, University of British Columbia, 1966. http://hdl.handle.net/2429/37660