Back to search

University of British Columbia

Millimeter-wave radiometer for the measurement of temperatures in hot transient plasma

Abstract

dc:description

A superheterodyne Dicke type radiometer suitable for the measurement of radiation from a high temperature plasma in the 35 GHz range has been developed. The radiometer employs a balanced mixer at the radiometer frequency, a 3.5 GHz parametric amplifier using a varactor diode as the first IF amplifier, a broad-band transistor amplifier at the second IF of 7Q MHz and a commutator detector. The performance of the radiometer has been measured by conducting hot load tests and by using an S-band argon noise source. The minimum detectable temperature change was found from the hot load tests to be 11 deg K for an output bandwidth of 0.32 Hz. However, from argon noise source measurements, a minimum detectable temperature change of 1.4 x 10³ deg K was determined for an output bandwidth of 6.4 KHz and 9.5 x 10³ deg K for an output bandwidth of 160 KHz. The equation for the minimum detectable temperature change for the Dicke radiometer has been deduced following conventional analysis. It has been found that there are two errors in Goldstein's derivation the effects of which cancel out and his final formula is correct. Thus, the change suggested by Ring does not appear to be valid. For the two channel subtraction radiometer it has been found that the expression given by Graham should be multiplied by √2. The d.c. radiometer has also been analysed and it has been found that its minimum detectable signal power is independent of both the radiometer bandwidth and the output bandwidth. The effect of noise at the radiometer input before the modulating switch has been investigated and it is shown that this noise could produce a cutoff condition in the Dicke radiometer and the two channel subtraction radiometer.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1966

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Carter, Charles Ruskin

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/37661

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Carter, Charles Ruskin. Millimeter-wave radiometer for the measurement of temperatures in hot transient plasma. master's thesis, University of British Columbia, 1966. http://hdl.handle.net/2429/37661