Back to search

University of British Columbia

Back-mixing in liquid-liquid extraction spray columns

Abstract

dc:description

Backmixing of the continuous phase was studied in liquid-liquid spray columns of various geometries, for various flowrates of the two phases, and for various drop size distributions. The dispersion or eddy diffusion model was used to characterize the axial mixing of the continuous phase. Axial concentration profiles were measured upstream, with respect to the continuous phase, from a distributor of sodium chloride tracer (soluble in the continuous phase only). The steady state form of the model was utilized to calculate axial eddy diffusivities from these results. The tracer studies showed that the axial eddy diffusivity is independent of the continuous phase flowrate and the column height. Axial eddy diffusivities between 7-ft.²/hr. and 31-ft.²/hr. were obtained in a 1½-in. I. D. column. Low dispersed phase flowrates and large drop sizes resulted in high axial eddy diffusivities. Increasing the column diameter to 3-in. resulted in superficial axial eddy diffusivities between 6.3 and 17.3 times larger. The hold-up of dispersed phase was measured by means of a piston sampler. The hold-up increases approximately linearly with increasing dispersed phase superficial velocity and tends to be slightly higher for increased continuous phase superficial velocities. A smaller drop size resulted in an increased hold-up. Drop size distributions were measured. They always show two peaks, one at 0.02-in. diameter, and the other at a much larger size, the actual value of which depends on the nozzle tip diameter used to disperse the drops. The mixing cell-packed bed analogy was used to predict Peclet numbers in a spray column. The agreement between these and measured Peclet numbers is good for drops of about 0.15-in. equivalent diameter but becomes progressively worse as the drop size is reduced.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemical and Biological Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1967

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Henton, Jeffrey Ernest

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/37797

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Henton, Jeffrey Ernest. Back-mixing in liquid-liquid extraction spray columns. doctoral thesis, University of British Columbia, 1967. http://hdl.handle.net/2429/37797