University of British Columbia
Condensation of steam in a packed column in direct contact with immiscible liquids
Abstract
dc:descriptionA packed condenser and the auxiliary equipment were designed, built and tested for the condensation of steam in direct contact with Aroclor 1242 and 1248, which are commercial heat transfer agents and are immiscible with water. The co-current flow of steam and liquid, through a four inch inside diameter column packed with three-eighth inch ceramic Raschig rings, was studied. The packing heights used in the condensation of steam were estimated from the liquid temperature profile in the column. The heights of the transfer units for condensation and the average volumetric overall heat transfer coefficients were calculated. The height of the transfer unit for condensation was found to be affected largely by the mean viscosity and the flow rate of the liquid. Two empirical equations have been developed to describe the results of this study. HCU = F ( μ ) (n) where n = 1. 10 for Aroclor 1242 and n = 1. 16 for Aroclor 1248 is mean viscosity of the Aroclor in centipoise. For Aroclor 1242, F= 0.0535 + 8.90 x l0⁻⁶ L when L ≤ 2290 and F =-0. 0737 + 6. 44 x 10⁻⁵ L when L > 2290. For Aroclor 1248, F = 0. 02765 + 1. 244 x 10⁻⁵ L. L is superficial mass velocity of the Aroclor in lb /hr. ft²
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science - MASc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Chemical and Biological Engineering
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 1966
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rai, Virendra Chandra
Rights
dc:rights- Statement dc:rights
-
- For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/37840