Back to search

University of British Columbia

Seismic performance evaluation of multi column bridge bent retrofitted with different alternatives

Abstract

dc:description

Highway bridges constitute a large portion of the national wealth and build up the foundation for economic development. Due to aging and deterioration, they require regular monitoring, evaluation and repair. More than 40% of Canadian bridges have crossed half of their anticipated service life. Many of these are structurally deficient and require major maintenance and rehabilitation. Although budget is allocated each year for maintenance and rehabilitation programme, the amount is usually small and covers only 30% to 70% of the actual maintenance needs. This fact raises the need for identifying bridges that require immediate attention where a significant portion of maintenance resources should be utilized. This study developed an integrated bridge prioritization index for a network of bridges to determine the prioritized work considering the importance of the bridge, cost associated with its rehabilitation and current condition. Once the bridge has been selected it is necessary to select proper retrofit techniques. In order to select a suitable retrofit technique this research has compared the performance of a pre-1965 designed multi column bridge bent retrofitted with different rehabilitation techniques, namely FRP jacketing, steel jacketing, concrete jacketing and Engineered Cementitious Composites (ECC) jacketing. The performance of the four different retrofitting strategies is compared in terms of base shear capacity demand ratio, ductility demand, residual drift and damage states obtained from nonlinear Incremental Dynamic Analysis (IDA) and static pushover analysis. Statistical comparisons of static (pushover) against dynamic analyses results have been performed in terms of performance criteria such as displacement and base shear at cracking, yielding and crushing. Moreover, this research assessed the fragility of this retrofitted multi column bridge bent under near fault and far field ground motions. The study aimed to capture the impact of different retrofit techniques on the vulnerability of a retrofitted bridge bent. Through rigorous analyses and applying multi-criteria decision making this study developed a decision making tool that will assist in identifying the most effective retrofitting scheme considering its performance under seismic hazards. The results showed that bridge bent retrofitted with ECC jacketing performed better and deemed to be the optimal retrofit alternative.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Billah, Abu Hena MD Muntasir

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/38250

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Billah, Abu Hena MD Muntasir. Seismic performance evaluation of multi column bridge bent retrofitted with different alternatives. master's thesis, University of British Columbia, 2011. http://hdl.handle.net/2429/38250