Abstract
dc:descriptionAn ultrahigh vacuum system has been constructed for the purpose of filling discharge tubes with gases without introduction of impurities. An ultimate pressure of 6 x 10⁻¹⁰ mm. of Hg. has been reached before filling. Two tubes have been constructed and filled with Neon without critical contamination.
Degree
thesis:*- Name thesis:degree_name
- Master of Science - MSc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Physics
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 1963
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Vanandel, Hendrikus Willem H.
Rights
dc:rights- Statement dc:rights
-
- For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/38306