Back to search

University of British Columbia

Response of underground power transmission cables subjected to earthquake induced permanent ground deformation

Abstract

dc:description

The aim of this study is to evaluate the response of underground power transmission cables subjected to earthquake induced permanent longitudinal and lateral ground movements. The experimental work related to this research involved full-scale physical modeling. The testing facility used for this project comprises a 2.5 m x 3.8 m soil chamber, with the capacity to subject buried transmission cables to large relative displacements. The buried cables were subjected to axial and transverse soil movements, and the corresponding longitudinal and horizontal transverse soil loads were measured. A total of 15 axial pullout tests and 10 lateral pullout tests were conducted for the cable with different burial depths. In the absence of guidelines available for buried underground cables, the results of the full-scale experimental studies, which provide first-hand information on the cable-soil interaction behaviour, were compared with the response predicted from previous research work and also those based on current pipeline design guidelines such as ASCE (1984) to assess the applicability of those guidelines for buried power transmission cables. To better understand the cable-soil interaction behaviour, 3D numerical models were created to simulate the longitudinal and transverse experimental test set-ups. Numerical models, with the help of parameters derived from the laboratory element testing, were calibrated and validated based on the experimental testing. A parametric study was conducted to study the effect of the cable/soil relative stiffness, the material model parameters, burial depths and cable/soil interface friction on the response of buried cables. Furthermore, numerical models were developed to study the effect of out-of-straightness in the cable on the longitudinal soil loads. An analytical procedure, verified with numerical simulation, was developed to calculate the additional axial soil loads on the buried cable with out-of-straightness. Based on the results of experimental and numerical simulation, nonlinear longitudinal and horizontal transverse soil spring models were developed. Then, the response of buried cable subjected to the longitudinal and transverse permanent ground deformation was assessed as a function of different ground deformation parameters. Finally, analytical procedures were also developed for the quick assessment of the response of the buried cable subjected to PGD.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ahmadnia, Alireza

Rights

dc:rights
Statement dc:rights
  • Attribution 3.0 Unported
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/39477

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ahmadnia, Alireza. Response of underground power transmission cables subjected to earthquake induced permanent ground deformation. doctoral thesis, University of British Columbia, 2011. http://hdl.handle.net/2429/39477