Back to search

University of British Columbia

The respiratory rate and volume of the guinea pig

Abstract

dc:description

The present methods for the measurement of respiratory rate and volume of laboratory animals have been reviewed. The review suggests that these methods leave much to be desired. For this reason an apparatus has been developed in the hope that it may overcome the difficulties associated with those described in the literature. The apparatus consists of a mechanism to interrupt a beam of light in time with the animal's breathing, and the signal so produced is amplified to close a double pole double throw relay. The state of the relay, open or closed, selects an arrester on either the air supply spirometer or the air receiver spirometer. When the animal breathes in the air supply spirometer is free to move and the air receiver is locked allowing air to be taken from the air supply spirometer only. On expiration the reverse situation is in effect. A stylus attached to each spirometer records the downward or upward travel and hence the volume on a kymograph drum. An electro-magnetic stylus records each inspiration on the kymograph and a five second timer writes a time base. A limited amount of data on female and male guinea pigs is presented to indicate the validity of the measurements made with the apparatus. Equations based on these data relating respiratory rate and volume of the guinea pigs to body weight have been derived. These equations are compared with those of other workers and suggest that the apparatus devised may be superior to those described in the literature.

Degree

thesis:*
Name thesis:degree_name
Master of Science - MSc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Animal Science
Grantor dc:publisher
University of British Columbia
Year dc:date
1954

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nordan, Harold Cecil

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/40503

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Nordan, Harold Cecil. The respiratory rate and volume of the guinea pig. master's thesis, University of British Columbia, 1954. http://hdl.handle.net/2429/40503