Back to search

University of British Columbia

The construction of an adiabatic calorimeter and its use in measuring specific heats

Abstract

dc:description

A fluidless adiabatic calorimeter was constructed and was used to measure the specific heats of manganese-aluminum-carbon and manganese-zinc-carbon alloys from -150° to 150°C. In an adiabatic calorimeter, the temperature of a shield surrounding the calorimeter vessel is kept at approximately the same temperature as that of the vessel, so that the thermal leakage between the two is reduced to a negligible quantity. Thus the ordinary rating period, in which the thermal leakage modulus is calculated, can be eliminated. Since leakage modulus variations are reduced by the adiabatic method, it can be used for large temperature rises, resulting in fast and accurate measurements. The aneroid (fluidless) adiabatic calorimeter eliminates stirring and evaporation errors, and makes possible measurements at extreme temperatures. The calorimeter consisted of a cylindrical silver-plated copper vessel surrounded by an electrically heated adiabatic shield and an evacuated outer case. A platinum resistance thermometer-heater was used to supply heat to the calorimeter vessel and to measure the vessel temperature. The heat input and the thermometer resistance were measured by using a potentiometer in conjunction with standard resistances. The thermometer was calibrated by measuring its resistance at -183, -40, 0, and 100°C. The calorimeter was calibrated from -150 to 150°C. The accuracy of the calorimeter was approximately 0.5%, the main error arising from the method of measuring the temperature of the calorimeter vessel. The specific heat curves of the single phase magnetic alloys Mn₃AIC and Mn₃ZnC were measured. A second order specific heat anomaly was found, as expected, for the ferromagnetic alloy Mn₃AlC at its Curie point, -10°C. Although the anomaly was close to the theoretical shape, dropping to zero over only a 10°C range at the Curie point, its maximum height was less than saturation magnetization measurements would indicate. The alloy Mn₃ZnC showed second order specific heat anomalies at -35°C, and at 65°C. This double specific heat anomaly indicates, in agreement with neutron diffraction results, a complex magnetic behaviour for the alloy. Although the high temperature Curie point anomaly did not have a sharp peak, the low temperature anomaly's shape approached that of the theoretical Weiss curve.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy - PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Metals and Materials Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1957

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Swanson, Max Lynn

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/40670

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Swanson, Max Lynn. The construction of an adiabatic calorimeter and its use in measuring specific heats. doctoral thesis, University of British Columbia, 1957. http://hdl.handle.net/2429/40670