Abstract
dc:descriptionHeat transfer measurements were made in a heat exchanger where air flows parallel to an unbaffled tube bundle and where steam is condensing inside the tubes. The tubes were one-inch outside diameter and were arranged in a square lattice with one-inch clearance between adjacent tubes. The Reynolds Number range covered in this investigation was 630 - 8220. Pseudo-j(h)-factors have been calculated for the air film in the central unit cell and are presented along with the results of Miller et al and Inayatov and Mikeev, who worked with other lattice arrangements. The present data are insufficiently numerous and too unreliable for empirical correlation, but they do show a trend which is consistent with the work of the above investigators. The temperature measurements showed an apparent dissymmetry inside the shell of the heat exchanger, and suggestions are made for the improvement of these measurements for more dependable results. Further work that can be done, using the present set-up with slight modifications, is also cited.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science - MASc
- Level thesis:degree_level
- master's
- Discipline thesis:degree_discipline
- Chemical and Biological Engineering
- Grantor dc:publisher
- University of British Columbia
- Year dc:date
- 1958
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Chandrasekharan, Kuppanna
Rights
dc:rights- Statement dc:rights
-
- For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/2429/40889