Development and evaluation of an interface pressure transducer for biomedical applications

Abstract

dc:description

The measurement of the interface pressure between a biomedical device and part of the human body is useful to aid in the design or improve the performance and safety of such devices. Therefore, a need exists for a transducer to measure interface pressure in these applications. The development and evaluation of an interface pressure transducer was the main goal of this research. Surgical retraction, surgical tourniquets and mammography were selected as demonstration applications for the developed transducer. These target applications were selected because they represented a wide spectrum of device and tissue characteristics and properties, and were in common use. A review of the available clinical, commercial and engineering literature identified a wide range of transducers and transducer technologies used for interface pressure measurement. The transducers included pneumatic/hydraulic, fibre-optic, strain based, capacitive and micromachined technologies. No standard method of measuring interface pressure was described and, in many cases, investigators cautioned against comparing-interface pressure measurements obtained using different measurement systems. From this review and an examination of the biomedical applications mentioned, the design criteria and optimal design specifications for an interface pressure transducer were defined. To gain a better understanding of the mechanical response of the interface between a device, transducer, and tissue to an applied loading, a preliminary finite element model was developed and studied. The model demonstrated the potential for shear stresses to develop between the transducer and interface materials. Furthermore a calibration system which simulated interface conditions was developed to evaluate both existing and developed transducers for use as interface pressure transducers. This evaluation demonstrated the lack of a transducer whose output was independent of the compliance of the interface materials. As well, an essential characteristic was identified for an effective interface pressure transducer that could be used in several applications where the interface material compliance was different. Based on the knowledge gained from the finite element analysis and existing transducer evaluation results, a novel interface pressure transducer was developed and evaluated both in the calibration system and via demonstration applications of surgical retraction and tourniquets. Under laboratory conditions in the calibration system, the transducer met many of the desired design specifications. The transducer was tested in the lab under both pneumatic and nonpneumatic tourniquet cuffs. The transducer worked well under the pneumatic cuff but required ] further development for use under the non-pneumatic cuff. The transducer was also integrated into a surgical retractor and evaluated in five clinical trials. It met many of the desired specifications for this application.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Paris-Seeley, Nancy J.

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/4103

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Paris-Seeley, Nancy J.. Development and evaluation of an interface pressure transducer for biomedical applications. master's thesis, University of British Columbia, 1996. http://hdl.handle.net/2429/4103