Back to search

University of British Columbia

Analysis of design factors influencing the oxygen transfer efficiency of a Speece Cone hypolimnetic aerator

Abstract

dc:description

The objective of this research was to characterize the performance of a downflow bubblecontact (DBCA) hypolimnetic aerator — Speece Cone-. The effect of two key design factors, inlet water velocity and the ratio of gas flow rate to water flow rate on four standard units of measure was examined: (a) the Oxygen Transfer Coefficient, KLa, corrected to 20°C, KLa₂₀ (hr­-¹), (b) the Standard Oxygen Transfer Rate, SOTR (g0₂.hr­-¹) (c) the Standard Aeration Efficiency, SAE (gO₂kWhr­-¹), and (d) the Standard Oxygen Transfer Efficiency, SOTE (%). Two sources of oxygen, Pressure Swing Adsorption (PSA) oxygen (87% purity) and air, were compared. KLa₂₀, SOTR, and SAE increased with an increase in the ratio of gas flow rate to water flow rate for both air and oxygen, over a range of 0.5% to 5.0%; while SAE deceased. An increase in inlet water velocity resulted in a decrease in KLa, corrected to 20°C, SOTR, and SAE, but an increase in the SOTE. Treatments on air showed similar, but much less dramatic effect of the gas flow rate to water flow rate ratio and water inlet velocity on KLa₂₀, SOTE, SAE, and SOTE, when compared to treatments on PSA oxygen. The best performance was achieved with an inlet water velocity of 6.9-7.6 ms­-¹ and oxygen flow rate to water flow rate ratio of about 2.5%. At this combination, the SOTE was about 66-72%.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kowsari, Assieh

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/4168

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kowsari, Assieh. Analysis of design factors influencing the oxygen transfer efficiency of a Speece Cone hypolimnetic aerator. master's thesis, University of British Columbia, 2008. http://hdl.handle.net/2429/4168